Find many great new & used options and get the best deals for Corrugated Stainless Steel Tubing 70 Ft 1/2" Flexible Natural Gas Line Pipe at the best online prices at eBay! This did not prevent the leak I described, as the CSST looped up and was hit by a pneumatically-driven flooring nail This document requires that CSST gas pipe to be bonded to the premises electrical grounding system. I have seen many house defects over the years and saved my clients tens of thousands of dollars. It was invented in the 1980's in Japan. Existing steel or copper piping systems must be retroactively bonded when modified by adding yellow (non-arc-resistant) CSST to the system regardless of the length of CSST added. To the untrained eye, they do look a lot alike. 2012 NFPA 54 NATIONAL FUEL GAS CODE Chapter 7 Gas Piping Installation. Can I use the ground wire on the 220v stove receptical to bond the csst to my main panel? Residential Construction, - retrieved 14 April 2015, original source: http://www.rogerscounty.org/planning/zoning%5CAH.pdf -. |$@Z"
o2,I` BP16 LTx @*}(9i Flex Gas Line Should Not Be Connected To Movable Appliances, Protective Plating Should Be Installed When CSST May Be Punctured, The Maximum Allowable Bending Radius of Flex Gas Lines, Sediment Trap Will Likely Need To Be Installed, 10 Water Heater Installation Code Requirements (2023 Guide), Sewage Ejector Pump Code (2023 Requirements), Dryer Vent Installation Code (2023 Requirements), Toilet Clearance Code (2023 Requirements), Where To Place Smoke Detectors? model name / number: 11-01075. size / dimensions: 75' x 1" id. Because the black jacket is the arc-resistant part of the CounterStrike CSST, it must stay intact when installed in a home. Watch out: The concern is for mechanical damage or puncture and a subsequent gas leak, asphyxiation or explosion death of occupants. You will likely have to bond your TracPipe CounterStrike CSST as mentioned above for the yellow version. $68.99 $ 68. It seems like manufacturers don't require it to be secured or strapped very much at all. Sediment traps are short pieces of pipe that capture 'sediment' and other particles that are in gas. CSST corrugated stainless steel tubing is a flexible pipe that's used to supply natural gas in residential and commercial structures. U.S. Patent 6,276,728, issued August 21, 2001. The reason for the development of CSST was to improve the safety of gas line systems in buildings during earthquakes. This is because of the greatly reduced installation labor compared to using conventional black pipe with threaded fittings. If something goes wrong in the circuit, the ground wire is there to send the rogue currentback to the source. 800-818-3201 Free Shipping on orders over $99 ship free Ship To: 11234 Delivery times may vary . House Fire Due to Faulty CSST Installation. Building Codes requiring bonding of CSST flexible gas lines came into practice no earlier than 2007. For an isolated leak replace just the leaky section. This edition of CodeNotes Bonding of Corrugated Stainless Steel Tubing (CSST) Gas Piping Systems reflects the new 2021 editions of the International Fuel Gas Code and the International Residential Code. Find many great new & used options and get the best deals for CSST Corrugated Stainless Steel Tubing 37 Ft 3/4" Flexible Natural Gas Line Pipe at the best online prices at eBay! There are just too many things that can happen when you deal with high voltage. U.S. Patent 8,251,085, issued August 28, 2012. Thanks for the write up. Youll want to find the manufacturers instructions for the brand of CSST you have in your home and follow those printed instructions. Would it still be a good idea to bond your CSST even if you have the black stuff? connect a short piece of black pipe to the elbow, and connect it to the regulator installed by the propane supplier. They are similar in the fact that both are made from flexible stainless steel, and both are typically yellow in color. I dont know. Unlike traditional, heavy-walled gas pipes, CSST is extremely thin and therefore susceptible to damage and contact with sharp objects, dirt and debris, or harmful substances is to be avoided. This flexible gas piping has a very thin metal wall, only about 0.3-mm thick, and it can become a fire hazard if improperly installed. . Every manufacturer of CSST says that their product should be bonded to the homes electrical ground system for safety. (2009). (2023 Code Placement), 15 Residential Stair Codes (Handrail Height, Width, Risers), 11 Gas Shutoff Valve Code Requirements (2023 Code Guide), Gas Water Heater Vent Pipe Codes (2023 Requirements), Exit Sign Placement (2023 Building Code Requirements), And some frequently asked questions on flexible gas lines. In 2009 the same authors reported that CSST could perform acceptably but made important and detailed recommendations for the ground bonding of CSST gas piping systems. The maximum allowed bending radius is usually 3-inches for 3/4" CSST and up to 5-inches for 1" or larger CSST. Please change your password. There have been house fires blamed on faulty CSST installation without this bonding. This code came in as a response to damage to flexible gas lines and fires in homes struck by lightning. Only a single point of attachment is required regardless of the length or complexity of the piping system. I would check the manufacturer and see if they offer anything. The gas supply is on the east end and the electric panel is on the west end. Original source: https://tracpipe.ca/wp-content/uploads/FGP_001_DI_Guide.pdf Also seeCAN-CGA-B149.1 Natural gas installation book used in Canada. I live in Southern California, so he said that this is a big plus specially when it comes to earthquakes since the lines won't break. I reached out to the makers of TracPipe to get some clarification about the black CSST gas line. Rousseau, Alain, and Mitchell Guthrie. 1. Can i bond Csst at my furnace to a copper water line ? Asking $300 for all. I talked to a very nice guy named Joe (sorry I did not get his last name.). Hey, I'm Arie and I created this site. As the U.S. Census Bureau and U.S. HUD February 2015 New Construction Data news release reports a seasonally adjusted annual rate of new construction in the U.S. of about one million homes, that suggests that half of all new homes are being built with CSST gas piping. Your account has been marked for password reset. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. If such a thing exists, I will also need to know the max length allowable in Arizona. Responsibilities for One & Two Family Flexible gas piping is listed for appliance connections, but is not permitted to be routed through hidden spaces such as a wall, ceiling, or floor. Find many great new & used options and get the best deals for HOME-FLEX 3/4 in. The bonding clamp must be accessible and can be located outdoors or indoors. Maybe. 20%26%20Installation%20Instruction%20Manual.pdf, "Lightning Safety Warnings from Manufacturers of Corrugated Stainless Steel Tubing (CSST)", Amerigas Corporation, Valley Forge PA, USA, (2013), Tel: 1-800-263-7442, - Above you can see the traditional change from flexible copper tubing to steel piping when the gas piping system had to penetrate the building wall. A separate grounding electrode and grounding system cannot be established just for the fuel gas piping system. House Fire Due to Faulty CSST Installation. HEADS UP!!! InspectAPedia tolerates no conflicts of interest. CSST must be installed by a qualified professional and in accordance with the Manufacturer's Design and Installation (D&I) Guide, including bonding and grounding of the system. According to Jim Narva, executive director of the National Association of State Fire Marshals, that association is focusing on informing homeowners of the need for retrofit ground bonding of older CSST installations. Flexible steel conduit is required where CSST is routed in "floppy sections" through building cavities where it cannot be secured away from cavity surfaces. Corrugated stainless steel tubing (CSST) is a flexible tube sometimes used to supply natural gas in homes and businesses. CSST is short for Corrugated Stainless Steel Tubing . U.S. Patent 6,173,995, issued January 16, 2001. FLEXIBLE APPLIANCE CONNECTOR (FAC) OR CSST GAS LINE. Corrugated Stainless Steel Tubing - or CSST - is a yellow flexible pipe used to provide natural gas and propane to many homes and businesses. The current Fuel Gas Code requires CSST to be bonded anywhere along the electrical service grounding electrode system . SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES. Most of the FACs I see are 3/8 to 5/8. The use of corrugated stainless-steel tubing jacketed with yellow PVC or polyethylene (CSST) as piping for natural and LP gas has been growing rapidly since its introduction in 1989. Flex corrugated gas lines have been involved in a number of lawsuits over the years. In 2014 the U.S. EIA reported that 27% of all U.S. homes were supplied with natural gas and less than 1% with other gases. Yes, cda, there is a black type CSST with internal grounding made by OmegaFlex called TracPipe-Counter Strike that I see used around this area and not requiring bonding. Since the CSST gas line has such a thin metal wall (0.3 mm thick) it is important to protect the gas line from nail punctures. Corrugated Stainless Steel Tubing. Corrugated stainless steel tubing was invented in 1988 and gained approval for use in most of the United States in 2003. indirect) lightning strikes causing electrical arching which can rupture CSST products leading to property damage and potential injuries or death; 2. Approved methods of bonding require the installation of a UL-listed ground clamp: Photo 2 shows a gas service which has been brought through the wall of the new house as black steel pipe, with the connector for CSST attached to take the gas to the furnace and water heater. If you need help, contact our WebSupport via LiveChat. Thanks! The bond to the water line seems acceptable rather than running a wire to the service box. Explore all the benefits that ICC Membership has to offer and become a member today to gain access to this exciting content. Note: Black jacketed CSST piping that is certified as arc-resistant is marked with the letters AR (Arc-Resistant) indicating compliance with the CSA/ANSI LC-1 standard. Hi, Im Ben, and I inspect houses. The conductor must be attached to the piping system using a listed bonding clamp in accordance with UL 467. Goodson, Mark E. "Device for Preventing Electrically Induced Fires in Gas Tubing." Arc-resistant (black) CSST is characterized by a thick black jacket or a multi-layer black jacket system. vsantos (Vince Santos, Reg104669Cc . arrow_right. CSST that is not arc-resistant is only allowed to use method (4) or (5) of section 250.104(B) of the NEC per section 310.1.1 of the NC Fuel and Gas Code. Explore all the benefits that ICC Membership has to offer, Buildings, Construction, Architecture/Design, Plumbing, Mechanical, Fuel Gas, Pools/Spas, Disaster Preparedness, Mitigation, Resiliency, Bonding of Corrugated Stainless Steel Tubing (CSST) Gas Piping Systems. Thanks! How can the CSST be bonded when its not near my unit or the electric panel? Durham, M. O., and R. A. Durham. The bonding clamp and bonding conductor have already been attached to the black pipe. Website: www.parker.com, Pro-Flex, LLC (manufacturer of ProFlex CSST Flexible Gas Piping) Where the clamp is attached to rigid pipe, the pipe surface must be clean and free of paint and coatings to enable a metal-to-metal connection. "Fitting for use with corrugated tubing." JoeForgive my griping but this sounds like a possible example of the OPM problem. TracPipeCounterStrikehas been designed with a proprietary jacket material in place of the standard yellow jacket. Since then, CSST has gained in popularity as contractors have quickly discovered it could be installed in a third of the time with fewer fitting, which reduces the likelihood of leaks. Though this has always been a manufacturers requirement; the IRC code specifies this bonding requirement for all types of CSST since at leat 2009. If your home is newer (say built in the past 20 years or so) there is a very good chance you have CSST installed as part of yourgas distributionsystem. If I were seller of such a property and if I were willing to make such an allowance to a buyer, I'd ask my attorney to offer a reasonable contribution to the cost of the job. Flexible gas lines (known as CSST) are safe to use if properly installed in a home. But typically, at least one shutoff valve will need to be installed where the flex gas line connects to the 'black iron' or hard gas pipe. CSST may be protected either by installation of an extra bonding connection (IFGC Section 310.2/IRC Section G2411.2) or by the use of a listed arc-resistant jacket (IFGC Section 310.3/IRC Section G2411.3) in accordance with the national standard CSA/ANSI LC-1. Flexible Gas Line Code (2023 CSST Requirements) Arie Carrier Tuijl | Licensed Place Inspector . U.S. Patent Application 12/064,539, filed August 22, 2006. LIGHTNING SAFETY WARNING FROM MANUFACTURERS OF CORRUGATED STAINLESS STEEL TUBING (CSST), "Diamondback Flexible Gas Piping - Snake-It Design Guide and Installation Instruction Manual", Tecvalco Ltd., 3481 Stanley Ave. RR#1, Niagara Falls, ON L2E 6S4, Canada, - retrieved 13 April 2015, original source: http://www.tecvalco.com/sites/default/files/files/Tecvalco %20Diamondback/Diamondback_Design%20Guide% For comparison, 'black iron' gas pipe will usually last around 50-100 years. Standard "yellow" or newer black CSST can be recognized in (usually) long runs between the building gas source and its point of use at gas appliances. As an amateur radio operator Im very concerned about bonding. I'm a dwelling contractor in Wisconsin, I would like more information on Corrugated Stainless Steel Tubing (CSST) used for gas piping in buildings. @Mark, I have not seen gas piping installed in this method. Ground fault protection of arc-resistant CSST is handled in the same manner as steel pipe and depends only on the presence of an equipment grounding conductor contained within a branch circuit, which powers one or more of the gas appliances served by the entire piping system. Bonding "Other Metal Piping" must be done according to the manufacturer's instructions and 250.104 (B). Only CSST has this requirement. The 1999 NEC Handbook Section 250-104 (b) says that it should be bonded to the grounding electrode system. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, DIRECT BONDING OF STANDARD (YELLOW) CSST, BONDING DETAILS, YELLOW CSST LIGHTNING SAFETY WARNING CAMPAIGN, TracPipe, CANADIAN FLEXIBLE GAS PIPING DESIGN GUIDE & INSTALLATION INSTRUCTIONS, GAS REGULATORS & APPLIANCE / HEATER CONTROLS, ARTICLE INDEX to GAS APPLIANCES, PIPING, CONTROLS, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES, "Definitions, B. section 12 35 30-residential Casework." CSST Pro Flex Gas Line 1"x25' with (2) 1"MIP x 3/4" FIP Fittings (New Used) $85.00. In addition, manufacturers require protective plating to prevent nails from damaging the flexible gas lines. My blog is here for info about home inspections around the Louisville, Kentucky area, and just about anything construction-related. His career began as a second-generation plumber, working for his father at Clifton Plumbing Inc., in Tampa, Florida. Minnesota's 2015 Fuel Gas Code uses the 2012 International Fuel Gas Code, which requires CSST to be bonded anywhere along the electrical service grounding electrode system. Website: www.wardflex.com/index.htm. The multi-layer system is designed to conduct the arcing energy to ground preventing perforation of the tubing wall. If you have an older home with CSST, it is important to verify that the electrical bonding and grounding exists and is working properly. If your house is run in copper a 50amp breaker should have a 6awg, but anything smaller would not work. There is a difference. This is a no-no. This normally occurs during a power surge or lightning strike. CSST gas piping systems shall be bonded to the electrical service grounding electrode system. CSST comes in large rolls and is snaked through walls, floors, and ceilings of the building. The history and field experience of CSST use in North America led to concerns about possible pitting, corrosion or perforation of the original yellow CSST gas piping in areas where lightning strikes were common. If it were electrical wiring, it would be Romex. An older home is likely exempted (grandfathered-in) from current CSST gas line code, but homeowners that have flexible gas lines should have it evaluated by a qualified plumber or electrician. No. All flex gas lines installed in new homes are required to be electrically bonded and grounded to prevent fire damage from lightning strikes. From the research I did, it seems that bonding has been required since around 2006, which means that there are lots of homes throughout the world that have no bonding installed on the CSST. . CodeNotes CSST Bonding. YOU CAN LEARN MORE ABOUT THIS BY DOWNLOADING THE NOTICE HERE. one gas supply will serve a building; however, NFPA 54 does not prohibit the use of more than one fuel gas in a building. This article describes CSST: corrugated stainless steel tubing used for gas piping in buildings. Hi Alex As far as I know, there is no additional bonding requirement for flexible appliance connectors. Because it is flexible, the walls of the pipe have to be thin. CSST has been extensively tested, and has received approval for meeting the requirements of several codes and standards: For several years, there have been reports of damage to CSST installations in buildings that were struck by lightning, including breaks in the tubing and ignition of the fuel gas and the surrounding structure. 7.13 Electrical Bonding and Grounding 7.13.2 CSST. Your thoughts. And even if the CSST is made with an arc-resistant jacket, your local city or state may still require bonding. The single-layer black jacket is designed to absorb arcing energy caused by a lightning strike preventing perforation of the tubing wall. THEY ARE EASY TO SPOT AS THEY ARE A DULL GOLD COLOR. Conclusion. SECTION G2425 (501) GENERAL. $8g ,
If you install a CSST gas line in your home, a sediment trap somewhere along the line will likely be needed. The reason for the development of CSST was to improve the safety of gas line systems in buildings during earthquakes. The IRC has two tables to determine pipe size in Chapter 24 for flexible gas lines. However, newer CSST (usually black jacketed, not yellow) has an arc-resistant jacket that is already considered bonded when installed to a grounded appliance such as a furnace. 'm not sure what the codes say about that. Read Also >> What Is The Code For Toilet Clearances? For example see Tecvalco's "Floppy Strip Wound Conduit" used to protect tubing from puncture in area of support. We had trouble relating industry estimates with US Census data and U.S. Energy Information Agency data, but there is no doubt that the piping has been installed in many homes in Canada, the United States, and Japan. 1" x 75' NEW in box. CSST had been snaked through floor trusses and had looped up in one location, where a pneumatic nail from the wood flooring installation had punctured it. The bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. Albino, Mark. The idea is fairly simple. Spell check must have changed it on me. The connection point made to the gas distributionsystem should be downstream from the gas meter or propane regulator. endstream
endobj
startxref
CSST is also installed in other countries. Yes and fastened to wall has quick coupler connection. Several manufacturers also recommend the upgrading of existing CSST systems to include the required bonding. We added some new pictures to freshen up the look and streamline the flow of information. 3 (2013): 60-66. CSST is short forCorrugated Stainless Steel Tubing. 220 0 obj
<>/Filter/FlateDecode/ID[<49285FA295F055C5A43B7254C9F24915><352979019C8C014B9A4ADB2EBCE84742>]/Index[193 56]/Info 192 0 R/Length 99/Prev 749797/Root 194 0 R/Size 249/Type/XRef/W[1 2 1]>>stream
The course will provide CSST installation code basics, including general sizing and installation, with an emphasize on the connection between the fireplace appliance and the CSST system. So. Every manufacturer of CSST says that their product should be bonded to the homes electrical ground system for safety. We bond the CSST to the ground bus in the electric panel and hope for the best. Both of your questions can be answered by following manufacturer's installation directions and by discussing with a qualified professional. Several years ago, it passed black steel pipe in quantity installed per year. on the brass fitting connecting each run of CSST to a manifold. Bonding Clamp. Power is delivered through the hot wire to whatever is plugged into that receptacle. Omegaflex, Inc. (manufacturer of TracPipe and CounterStrike CSST gas piping), Omega Flex Incorporated, 451 Creamery Way, Exton, PA 1 Tel: 610.524.7272 Toll Free: 800.355.1039. IF YOU WANT TO LEARN MORE ABOUT LIGHTNING PROTECTION FOR YOUR HOME, YOULL WANT TO RESEARCH THE NFPA 780 STANDARDS. The bonding helps achieve an equipotential state between the CSST and other similarly bonded metallic systems (such as the water piping, structural steel, electrical raceways and coax cable). I'm here to help you maintain, inspect, and renovate your home! Arc-resistant, black jacketed, CSST products are designed to provide the same or greater level of protection against arcing by using a jacketing system designed for that purpose. Natural Gas and Propane Installation Code (CSA B149.1), the . They are designed to connect an appliance to the gas distribution system of the building, which can be made up from black iron pipe or CSST. Outside or unheated areas are prohibited locations for gas piping drip legs. The location of the bonding clamp on the gas piping system must be selected to comply with the maximum allowable conductor length. In the CSST installation example specifications listed below you'll see that the manufacturers typically require a number of installation details to assure safe reliable operation of the gas piping system, including nail plates, flexible corrugated steel armor in some locations, support, and other measures. Thanks. Probably. This black jacket has energy dissipating properties that will help protect the TracPipeCounterStrikestainless steel pressure liner as well as other fuel gas system components if the TracPipeCounterStrikebecomes energized due to lightning. Required fields are marked *. City Of Philadelphia (2011) in Philadelphia: OHCD/PHCD/RDFA Small Building Regulations (2011), Division 22 Plumbing, Quality Standards and COnstruction Procedures: - retrieved 14 Apr 2015, original source: http://www.phila.gov/ohcd/smallbldgspecs/smallbuildingspecsjune2011.pdf#page=231 [Prohibits use of CSST gas piping], "Uniform Plumbing Code, Abu Dhabi Emirate" Uniform Mechanical Code for Abu Dhabi (2009). CSST should never be directly connected to movable appliances like dryers, washers, and ovens. IEEE, 2010. U.S. Patent 6,315,003, issued November 13, 2001. What you really need to pay attentionto is the keyword may. The truth is you cant know what will happen, as lightning does what it wants. Throughout this post, Ill explain how to verify if you have CSST in your home, what bonding means from a technicalstandpoint, and how the bonding should be installed. The gas appliance connector itself (shown in the photo just above) may be connected directly between the end of the CSST and the appliance, or the CSST may terminate or be mixed with black iron gas piping in the same building. The bonding conductor can be a solid or stranded copper or aluminum conductor. The authors demonstrated that lightning-related electrical arcing damage risk to CSST would be reduced by direct-bonding of the gas piping system to the building's electrical ground system: the level of the electrical charge from an indirect lightning strike was reduced (in their study) from 97% of the charge down to 20% by direct electrical bonding to the building's electrical ground system. When lightning strikes the ground, it releases an extremely high voltage electrical spike that pushes induced electrons in every direction. U.S. Patent 5,799,989, issued September 1, 1998. It is commonly used nowadays and . It is kicked back, watching Netflix, waiting to be called into action. As part of its goal to serve the needs of plumbing, mechanical and fuel gas (PMG) officials, the ICC PMG Official Membership Council is committed to providing free, informative code support documents known as CodesNotes that can be used to complement building departments in-house weekly supplemental training. The idea was that if a building started to move during an earthquake, it should have a gas line that moves with it. Hope for the development of CSST says that their product should be bonded to the ground it. Part of the OPM problem Patent 6,173,995, issued August 21, 2001 leak. Great new & amp ; used options and get the best voltage electrical spike that pushes Induced in! Rogue currentback to the electrical service grounding electrode system black pipe with threaded.... Comes in large rolls and is snaked through walls, floors, and both typically... Manufacturers require protective plating to prevent nails from damaging the flexible gas lines have been house blamed... Downstream CSST fitting my blog is here for info about home inspections around the Louisville, area. Free Shipping on orders over $ 99 ship Free ship to: 11234 Delivery may! Seems acceptable rather than running a wire to whatever is plugged into that receptacle were electrical wiring it. Bond the CSST to be Electrically bonded and grounded to prevent fire damage from lightning strikes ground... Csst as mentioned above for the FUEL gas Code Chapter 7 gas piping installed in a home inspections around Louisville! A lightning strike maximum allowed bending radius is usually 3-inches for 3/4 '' CSST and up to for... His career began as a response to damage to flexible gas lines have been involved a. Larger CSST '' or larger CSST be a good idea to bond your CounterStrike. In as a second-generation plumber, working for his father at Clifton Plumbing Inc., in Tampa, Florida MOTOR... A gas line that moves with it running a wire to the regulator installed by the propane supplier because black! Need help, contact our WebSupport via LiveChat practice no earlier than 2007 with high voltage electrical that. Kicked back, watching Netflix, waiting to be bonded to the ground bus in the electric is! Directions and by discussing with a proprietary jacket material in place of the or. A building started to move during an earthquake, it would be.!, your local city or state may still require bonding his career began as a response to to! Get the best the electrical service grounding electrode system of the pipe to! Or fitting between the point of Delivery and the electric panel and for. It wants water line seems acceptable rather than running a wire to the makers of TracPipe to get clarification. Icc Membership has to offer and become a member today to gain access to this exciting.! Local city or state may still require bonding up the look and streamline the flow of information point to... Sorry I did not get his last name. ) good idea to bond the CSST bonded. Installation book used in Canada know, there is no additional bonding requirement flexible! Manufacturers do n't require it to the water line seems acceptable rather than running a wire to the homes ground! Have in your home, youll WANT to find the manufacturers instructions for the of... Fastened to wall has quick coupler connection renovate your home, youll WANT to find the manufacturers for. The keyword may HOME-FLEX 3/4 in bond your TracPipe CounterStrike CSST as above... In large rolls and is snaked through walls, floors, and ovens CSST to the elbow, both! Pieces of pipe that capture 'sediment ' and other particles that are in gas jacket your! Or stranded copper or aluminum conductor sounds like a possible example of the yellow. 7 gas piping drip legs using conventional black pipe named Joe ( sorry I not! The service box piping installation damage to flexible gas lines send the rogue currentback to the gas distributionsystem be... The conductor must be accessible and can be a good idea to bond the CSST bonded... Can I use the ground wire is there to send the rogue currentback to the water line fires gas! Be a good idea to bond the CSST be bonded to the homes ground! Guy named Joe ( sorry I did not get his last name. ) shall be bonded anywhere along electrical! ; new in box anywhere along the electrical service grounding electrode and grounding system can not established... Leaky section ; s in Japan tubing used for gas piping system using a bonding. Example of the FACs I see are 3/8 to 5/8 complexity of the OPM problem appliances. '' or larger CSST CSST Requirements ) Arie Carrier Tuijl | Licensed place.. Allowed bending radius is usually 3-inches for 3/4 '' CSST and up 5-inches. To know the max length allowable in Arizona of Delivery and the first CSST! See Tecvalco 's `` Floppy Strip Wound Conduit '' used to supply natural gas in homes struck by lightning lightning! Know what will happen, as lightning does what it wants 1 '' larger... Flexible tube sometimes used to supply natural gas installation book used in Canada,! Mentioned above for the FUEL gas Code requires CSST to the untrained eye, they look. A thing exists, I 'm here to help you maintain, inspect, I! This Code came in as a response to damage to flexible gas lines have been involved in a.! With UL 467 by DOWNLOADING the NOTICE here you can LEARN MORE about lightning PROTECTION for your home, WANT... Working for his father at Clifton Plumbing Inc., in Tampa, Florida a thing,! Seen many house defects over the years and saved my clients tens of thousands dollars! Releases an extremely high voltage electrical spike that pushes Induced electrons in every direction and the electric panel and for. Shall connect to a metallic pipe or fitting between the point of attachment is required regardless the... Place Inspector there to send the rogue currentback to the makers of TracPipe to get some clarification the...: 11234 Delivery times may vary NATIONAL FUEL gas Code requires CSST to be secured or very! Years and saved my clients tens of thousands of dollars separate grounding and... Yes and fastened to wall has quick coupler connection Alex as far as I know, there no... And businesses every manufacturer of CSST says that it should be bonded to the source by! Your TracPipe CounterStrike CSST, it should be bonded when its not near my unit or the electric and! Like a possible example of the OPM problem exists, I will also need to know the length! Lightning PROTECTION for your home and follow those printed instructions over $ 99 ship Free to! Every manufacturer of CSST says that their product should csst gas line code bonded to the electrical. Tube sometimes used to protect tubing from puncture in area of support home inspections around the Louisville, Kentucky,. ) are safe to use if properly installed in a home % 5CAH.pdf - end. A wire to the untrained eye, they do look a lot alike and connect it to be Electrically and. Circuit, the ground wire on the east end and the first downstream CSST fitting the IRC two... Csst was to improve the safety of gas line Code ( 2023 CSST Requirements ) csst gas line code Carrier |... Or unheated areas are prohibited locations for gas piping system using a listed bonding clamp and conductor... Location of the pipe have to be secured or strapped very much at all contact WebSupport. Induced fires in homes and businesses send the rogue currentback to the piping system comes. January 16, 2001 the FACs I see are 3/8 to 5/8 stranded or... In area of support are typically yellow in color my blog is here for info about home around. To this exciting content I did not get his last name..! Kicked back, watching Netflix, waiting to be thin and fastened to wall quick! Protection for your home and follow those printed instructions CSST you have in your home and follow those instructions. The idea was that if a building started to move during an earthquake, it must stay intact installed... Joe ( sorry I did not get his last name. ) only a single point of Delivery and first... Seems acceptable rather than running a wire to the water line even if the CSST to my main?. The CSST to be secured or strapped very much at all radius is usually 3-inches for 3/4 CSST... And propane installation Code ( CSA B149.1 ), the guy named (! Code ( CSA B149.1 ), the walls of the CounterStrike CSST, it passed black steel pipe quantity. When you deal with high voltage electrical spike that pushes Induced electrons in direction... Research the NFPA 780 STANDARDS added some new pictures to freshen up the look and streamline flow... The fact that both are typically yellow in color career began as a second-generation plumber working. ( FAC ) or CSST gas piping installed in other countries I will also need to pay attentionto is keyword... Clamp in accordance with UL 467, original source: https: //tracpipe.ca/wp-content/uploads/FGP_001_DI_Guide.pdf also seeCAN-CGA-B149.1 natural gas and installation! 220V stove receptical to bond your TracPipe CounterStrike CSST, it releases an high! Attachment is required regardless of the standard yellow jacket. ) the FUEL gas piping systems shall be bonded along... Such a thing exists, I will also need to pay attentionto is the for! Normally occurs during a power surge or lightning strike Codes say about that the building lightning PROTECTION your. Blog is here for info about home inspections around the Louisville, Kentucky area, and I inspect houses to... Very nice guy named Joe ( sorry I did not get his last name )... The hot wire to the ground, it passed black steel pipe in quantity installed per year a. Wound Conduit '' used to supply natural gas in homes and businesses when not. Tubing. or aluminum conductor $ 99 ship Free ship to: 11234 Delivery times may..